6.
Assembling the
booster pump series
01 - 03
1.
Place the HP outlet flange on the desk
and mount the O-ring and 2 pins.
2.
Align the port plate-out on the two pins
and mount the O-ring on the port plate.
WARNING:
Do not use silicone when assembling the
iSave. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolutely clean before mounting.
Lubrication:
•
To prevent cold welding, Danfoss
recommend to use thread lubricant for
all screw threads for installing the iSave
and first tighten the screws by hand.
If using any grease inside the unit it should
be Cassida RLS 00 or equivalent. Use only
the smallest possible amount.
•
It is important to lubricate ALL parts to be
assembled with clean filtered water
(Especially all PEEK parts).
3.
Turn the stator with the two holes for
the lifting eye closest to the port plate
and position the stator on the 2 pins.
4.
From down side up and by hand,
screw in two bolts in the stator.