Operation guide | iSave 40
58
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
7.
Disassemble the bell housing from the
booster pump by unscrewing the 4
bolts in the bell housing.
8.
It is also possible to disconnect the
complete unit from the motor first.
In this case, please follow step 1, 5, 6
and 7 afterwards. Assembly of the
unit in reverse order.
9.
After the pressure exchanger is released
from the booster pump, remove the two
guide pins and the O - rings.
5.
To disconnect the bell housing, unscrew
the 4 bolts on the electric motor.
6.
Carefully pull and lift the booster pump
from the electric motor.