24
•
Installing Xtium-CL MX4
Xtium-CL MX4 User's Manual
Information Field Description
Field
Description
Serial Number
[Read-Only]: Serial Number of the board
Hardware ID
[Read-Only]: This field identifies hardware changes that affect the
operation of the board.
Possible values are:
•
0x0000000000000000: Rev A1
•
0x0000000000020000: Rev A2
Hardware Configuration [Read-Only]: This field will state the presence or absence of optional
components. Currently there are no optional components available.
ECO Number
[Read-Only]: Indicates the last Engineering Change Order applied to
the board.
Note: For boards Rev A1 shipped with driver 1.00, this entry will
show 0.
User Interface Outputs
[Read-Only]: Number of available user interface outputs on the
board. Possible values are:
•
4: Rev A1
•
8: Rev A2
Note: For boards Rev A1 shipped with driver 1.00, this entry will
show 0.
General Input Opto
Read-Only]: Type of opto-coupler on the board. Possible values are:
•
TLP130 (Default)
•
IL208
Note: Boards shipped with driver 1.11 or earlier will show Default.
User Data
Read/Write]: This is a 64 byte general purpose user storage area.
For information on how to read/write this field at the application
level, contact Teledyne DALSA Technical Support.
User Interface GIOs
Reservation
[Read/Write]: Use this field to reserve User Interface GIOs for use
by the acquisition module.
To specifiy the GIO reservations, click on the ‘Value’ field to open
the configuration dialog box. Disable any GIO reservations that are