68
Spyder2 User’s Manual
03-32-10091-04
DALSA
Code Command
Short
Form
Parameters Description
27 set_data_mode
sdm i
Set the data mode of camera
output to:
0
: 8-bit, A/B/C/D ports,
single processor
1
: 10-bit, A/B/C and D/E/F
ports, single processor
2
: 8-bit, A/B and D/E ports,
dual processor
3
: 10-bit, A/B/C and D/E/F
ports, dual processor
28
set_digital_offset
sdo
t i
Subtracts the input value from
the video signal prior to the
PRNU correction. The first
parameter is the tap selection
either
1
or
0
for all taps. The
second parameter is the offset
in a range from
0
to
511
. Use
in calibrated mode only.
29
set_exposure_mode
sem
i
Set the exposure mode:
1
: Internal SYNC and PRIN,
max line rate and exposure
time, factory setting
2
: Internal SYNC and PRIN,
programmable line rate and
exposure time using
commands
ssf
and
set
3
: External SYNC, internal
PRIN, maximum exposure
time
4
: Smart EXSYNC
5
: External SYNC and PRIN
6
: External SYNC, internal
PRIN, programmable
exposure time
30
set_exposure_time
set
f
Set the exposure time in
exposure mode 2 or 6. Value
will be a floating point number
in µsecs. For allowable range,
see the camera help screen (
h
command).
31 set_fpn_coeff
sfc i
i
Set the FPN coefficient. The
first parameter is the pixel
number within the range of 1
to the sensor pixel count. The
second value is a specified
value within the range
0
to
127
.
Summary of Contents for Spyder2 S2-1-40 Series