3.4 Startup
When the camera is first started, it must perform several actions before it is ready for
imaging. This startup routine takes approximately 15 seconds, and follows this sequence:
1.
Initializes the camera and all internal hardware.
2.
Loads the last settings saved to non-volatile memory, including the last set of video
correction coefficients, if previously saved.
3.
Restores user settings if previously saved, otherwise factory settings.
4.
Performs a memory test and voltage test and reports an error if any occurred.
After this startup sequence is complete, the camera will return either the prompt "OK>" if
no error occurred, or an error code if a problem has been discovered.
3.5 Saving and Restoring Settings
The camera provides a number of commands for restoring, storing, and saving settings.
•
To restore the original factory settings, use the command
rfs
. The FPN and PRNU
coefficients are reset to 0.
•
To save all current settings to EEROM, use the command
wus
. The camera will
automatically restore the saved user settings when powered up.
•
To save all current pixel coefficients to EEROM, use the command
wpc
.
•
To restore the last saved user settings and the FPN and PRNU coefficients, use the
command
rus
.
Figure 8: Saving and Restoring Settings
Factory
Settings
User
Settings
Current
Session
wus,rus,
wpc
commands
rfs
command
Summary of Contents for Spyder2 S2-1-40 Series
Page 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...