60
Spyder2 User’s Manual
03-32-10091-04
DALSA
•
Decimal value representing sum of all informal message codes caused by last
command executed.
•
Decimal number representing sum of all pending warning values from all monitoring
tasks.
Example: value returned following a ccf command
gps
2 0 192 33
The returned value, 2 0 192 33, reads as follows:
Returned value
Description
2
Command code: correction_calibrate_fpn
0
Error code: successful
192
Informal message: code 64 + code 128
33
Monitoring task message: code 1 + code 32
The following tables list the codes for errors, informal messages, and monitoring task
messages. (Refer to section E7 for a list of all available commands.)
Error Codes
Cod
e
Description
Suggested Cause
0
Command executed successfully
Command executed without major error
detected
1
Internal camera error (PIXEL
INDEX)
Internal software error trap
2
Internal camera error (RESULT
CODE)
Internal software error trap
3
Invalid command
Command not recognized
4
Command parameters incorrect
or out of range
Command parameters are invalid or out of
range
5
Command not available in
current exposure mode
ssf
and
set
are allowed only in mode 2
(
ssf
and
set
) and in mode 6 (
set
)
6
Command available in
CALIBRATED mode only
ccf
,
ccp
7
Command available in
UNCALIBRATED mode only
cao
,
cag
8
Command not available in
VIDEO TEST mode
sao
,
sg
9
Start value must be an odd
number less than the even
numbered end value
roi
: invalid starting or ending pixel index
10
Camera memory check failure
Memory test of external RAM failed
11
Unable to configure DSP
DSP (FPGA) configuration failure
12
DSP configuration reset failure
DSP (FPGA) could not be placed in
configuration mode
13
Get line process command timed
out, check for the presence of
external signals
gl
,
gla
,
cao
,
cag
,
ccf
,
ccp
timed out.
Current exposure mode requires external
SYNC, however SYNC signal not present
Summary of Contents for Spyder2 S2-1-40 Series
Page 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...