35
Spyder2 User’s Manual
03-32-10091-04
DALSA
Location Value
Description
5
Line sum LSB
6
Line sum MID
7
Line sum MSB
Use these values to help calculate line
average
8 0
9
Pixels above threshold LSB
10
Pixels above threshold
MSB
11
Pixels below threshold LSB
12
Pixels below threshold
MSB
Monitor these values (either above or below
threshold) and adjust camera gain to keep
these values relatively constant. This
provides a basis for automatic gain control
(AGC)
13
Derivative line sum LSB
14
Derivative line sum Mid
15
Derivative line sum MSB
Use these values to focus the camera.
Generally, the greater the sum the greater the
image contrast
16
0
Test Pattern
The camera can generate a test pattern to aid in system debugging. Use the command
svm 2
to activate the test pattern. The test pattern is a ramp from 0 to 255DN, then starts
at 0 again. Use the test pattern to verify the proper timing and connections between the
camera and the frame grabber.
3.18 Monitoring the Camera
The camera is equipped with a red/green LED used to display the operational status of
the camera. The following table summarizes the operating states of the camera and the
corresponding LED states:
LED state
Priority Camera
Status
Condition
Blinking RED
1
Error
Fatal hardware failure
Steady RED
2
Warning
Monitoring task failure
Blinking GREEN
3
Progress
Lengthy operation in progress
Steady GREEN
4
OK
Healthy
Note:
When more than one condition is active, the LED indicates the condition with the
highest priority. Error and warning states are accompanied by corresponding messages
further describing the current camera status.
Summary of Contents for Spyder2 S2-1-40 Series
Page 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...