7
Spyder2 User’s Manual
03-32-10091-04
DALSA
Optical Interface
Units
Notes
Sensor Alignment x, y
z
0
z
Parallelism/Tilt
µm
mm
°
µm
±180
17.52 ± 0.25 (C-Mount)
46.50 ± 0.25 (F-Mount)
± 0.6
<175
Die Surface Flatness
µm
100
Lens Mount
C or F mount
Camera Thread
M42x1
Mechanical
Interface
Units
Notes
Camera Size
mm
50x85x50
Mass Kg
<450g
Connectors
data connector
power connector
MDR26 (female)
Hirose 6-pin (male)
Electrical Interface Units
Min
Nom
Max
Notes
Input Voltage
Volts
+12 to +15
Power Dissipation
W
<5
Operating
Temperature
°C
10
50
Measured at
the front
plate.
Camera
Performance
Units
Min.
Nom.
Max.
Notes
Line Rate
kHz
1
65 (512)
35 (1024)
18 (2048)
Data Rate
MHz
40
40
Data Format
8 bit
10 bit
8 or 10 bit
user
selectable.
Nominal Gain Range
dB
-10
+10
Dynamic Range
DN:DN
330:1 500:1
Pixel Response Non-
Uniformity (PRNU)
uncorrected
corrected (ECD/ECE)
DN
5
1.2/1.5
23
6/8
1
FPN
uncorrected
corrected
DN p-p
3.5
1
8
3