22
Spyder2 User’s Manual
03-32-10091-04
DALSA
3.6 Setting Baud Rate
To set the speed of the camera serial communication port, use the command:
Syntax:
sbr i
Syntax Elements:
i
Baud rate. Available baud rates are:
9600
(Default),
19200
,
57600
, and
115200
.
Notes:
•
Power-on rate is always 9600 baud.
•
The
rc
(reset camera) command will
not
reset the camera to
the power-on baud rate.
Example:
sbr 57600
3.7 Setting the Data Mode
To select the camera output mode, use the command:
Syntax:
sdm i
Syntax Elements:
i
0
8-bit, using port A for single processor configuration
1
10-bit, using ports A and B for single processor configuration
Notes:
•
To obtain the current data mode, use the command
gcp
.
Example:
sdm 0
3.8 Setting the Video Mode
The video mode sets whether the camera is running in calibrated or uncalibrated mode,
or if it is generating a test pattern.
To set the video mode, use the command:
Syntax:
svm i
Syntax Elements:
i
Video mode to use. Allowable values are:
0
Uncalibrated video, deactivated video correction
1
Calibrated video, activated video correction
2
Test pattern right
Notes:
•
To obtain the current video mode, use the command
gcp
.
Example
svm 1
Summary of Contents for Spyder2 S2-1-40 Series
Page 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...