67
Spyder2 User’s Manual
03-32-10091-04
DALSA
Code Command
Short
Form
Parameters Description
from 1 to sensor pixel count.
13 get_prnu_coeff
gpc i
Read the PRNU coefficient for
the pixel indicated by the
parameter in a range from 1 to
the sensor pixel count.
16
get_processing_status
gps
Read the status of last
executed command and coded
value for all pending
monitoring task warnings.
17 get_sensor_serial
gss
Read the sensor serial number.
18
help
h
Display the online help.
19 region_of_interest
roi i
i
Set the pixel range for reading
end-of-line statistic and for the
region of pixels used in the
cag
,
cao
,
gl
,
gla
,
ccf
, and
ccp
commands. Pixel start and
end values in a range from 1 to
sensor pixel count.
20
reset_camera
rc
Reset the entire camera
(reboot).
21 reset_pixel_coeffs
rpc
Reset the pixel coefficients to
0.
22
restore_factory_settings
rfs
Restore the camera’s factory
settings. FPN and PRNU
coefficients reset to 0.
23 restore_user_settings
rus
Restore the camera's last saved
user settings and FPN and
PRNU coefficients.
24
set_analog_offset
sao
t i
Set the analog offset. The first
parameter is the tap selection
either
1
or
0
for all taps. The
second parameter controls the
digital analog convertor
(DAC), in a range from
0
to
1023
, which sets analog offset.
Offset increases with higher
values.
25 set_baud_rate
sbr i
Set speed of serial
communication port. Baud
rates:
9600
(default),
19200
,
57600
, and
115200
.
26
set_camera_id
sci
s [s]
Set camera ID. The first
parameter is a character
A
to
Z
,
or
0
to
9
. The second optional
parameter is the serial number
of the addressed camera.
Summary of Contents for Spyder2 S2-1-40 Series
Page 10: ...10 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 38: ...38 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 44: ...44 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 72: ...72 Spyder2 User s Manual 03 32 10091 04 DALSA ...
Page 74: ...74 Spyder2 User s Manual 03 32 10091 04 DALSA ...