74
•
Operational Reference
Linea SWIR GigE Series Camera
Acquisition and Transfer Control Feature Descriptions
The following table describes the parameters along with the view attribute and minimum camera
firmware version required. The Device Version column indicates which parameter is a member of
DALSA’s Features Naming Convention (denoted by DFNC), versus the GenICam Standard Features
Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As the Linea SWIR GigE camera’s capabilities evolve, the device version tag will
increase, identifying the supported function package. New features for a major device version
release will be indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
Acquisition Status
Selector
AcquisitionStatusSelector
Selects the internal acquisition signal to read
using AcquisitionStatus.
1.00
Expert
Acquisition Trigger Wait
AcquisitionTriggerWait Device is currently waiting for a trigger to
capture one or more frames.
Acquisition Active
AcquisitionActive Device is currently doing an acquisition of one or
more frames.
Acquisition Status
AcquisitionStatus
Reads the state of the internal acquisition signal
selected using the AcquisitionStatusSelector
feature.
1.00
Expert
Acquisition Mode
AcquisitionMode
Set the acquisition mode of the device. It
defines the number of frames to capture during
an acquisition and the way the acquisition stops.
1.00
Beginner
Single Frame
SingleFrame One frame is captured for each AcquisitionStart
Command. An AcquisitionStop occurs at the end
of the Active Frame.
Multi-Frame
MultiFrame A sequence of frames is captured for each
AcquisitionStart Command. The number of
frames is specified by AcquisitionFrameCount
feature. An AcquisitionStop occurs at the end of
the Active Frame(s)
Continuous
Continuous Frames are captured continuously with
AcquisitionStart until stopped with the
AcquisitionStop command.
Acquisition Frame Count
AcquisitionFrameCount
Number of frames to be acquired in MultiFrame
acquisition mode.
1.00
Beginner
Acquisition Arm Cmd
AcquisitionArm
Arms the device before an AcquisitionStart
command. This optional command validates all
the current features for consistency and
prepares the device for a fast start of the
acquisition. If not used explicitly, this command
is automatically executed at the first
AcquisitionStart but will not be repeated for
subsequent ones unless a data transfer related
feature is changed in the device. (WO)
1.00
Guru
Acquisition Start Cmd
AcquisitionStart
Start image capture using the currently selected
acquisition mode. The number of frames
captured is specified by AcquisitionMode feature.
(WO)
1.00
Beginner
Acquisition Stop Cmd
AcquisitionStop
Stops the Acquisition of the device at the end of
the current frame unless the triggerFrameCount
feature is greater then 1. (WO)
1.00
Beginner