Implementing Trigger-to-Image Reliability
•
107
Implementing Trigger-to-Image
Reliability
Overview
In a complex imaging system many points of possible failure exist
–
from acquisition to processing
and transmission. Teledyne DALSA provides features, events and I/O signals that provide the
system designer with the tools to qualify the system in real time.
The Teledyne DALSA website provides general information, FAQ and White Paper download about
the Trigger-to-Image Reliability (T2IR) framework in hardware and Sapera LT software SDK.
http://www.teledynedalsa.com/imaging/knowledge-center/appnotes/t2ir/
T2IR with Line2
Linea Lite provides a number of features for system monitoring:
•
Built-in Self-Test on power-up and reset after firmware change
•
Image Buffer Accumulation
–
Count Status
•
Image Buffer Memory Size
•
Packet Resend Buffer Memory Size
•
Internal Temperature Reporting
•
In Camera Event Status Flags
•
Invalid External Trigger
•
Image Lost
•
Packet Resend & Related Status
•
Ethernet Pause Frame Requested
Linea Lite Features for T2IR Monitoring
The following table presents some of the Linea Lite camera features a developer can use for T2IR
monitoring. The output line signals would interface to other external devices.
Camera Status Monitoring
Device Built-In Self Test
deviceBIST
Device Built-In Self Test Status
deviceBISTStatus
Device Temperature Selector
DeviceTemperatureSelector
Device Version
DeviceVersion
Firmware Version
DeviceFirmwareVersion
Last firmware update failed
FirmwareUpdateFailure
Manufacturer Part Number
deviceManufacturerPartNumber
Manufacturer Info
DeviceManufacturerInfo
Preliminary