Linea Lite GigE Series Camera
Operational Reference
•
67
counterStartSource
Select the counter start source. Counter increments from
0 to the value of the counterDuration feature.
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counter starts on the reception of the Acquisition Start
event.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start
event.
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End
event.
Rejected Trigger
InvalidTrigger Counter starts on the reception of an Invalid Trigger
event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start event.
Line 1
Line1 Counter starts on the specified transitions on Line 1.
See Input Signals Electrical Specifications.
Line 2
Line2 Counter starts on the specified transitions on Line 2.
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1 End
event.
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger which
starts the counter. This is only applicable when the
counterStartSource feature selects a physical Line.
Expert
DFNC
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the
selected Line.
Counter Incremental
Source
counterIncrementalSource
Select the event source which increments the counter.
The
diagrams for the supported events.
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counts the number of Acquisition Start events.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
Exposure End
ExposureEnd Counts the number of Exposure End events.
Frame Start
FrameStart Counts the number of Frame Start events.
Rejected Trigger
InvalidTrigger Counts the number of Invalid Trigger events.
Line 1
Line1 Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting).
See Input Signals Electrical Specifications.
Line 2
Line2 Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting).
Internal Clock
InternalClock The counter increments on each microsecond tick of the
device internal Clock.
Timer 1 End
Timer1End Counts the number of Timer 1 End events.
Counter Incremental Line
Activation
counterIncrementalLineActivation
Selects the counter signal activation mode for line inputs.
The counter increments on the specified signal edge or
level.
Expert
DFNC
Rising Edge
RisingEdge Increment the counter on the rising edge of the selected
I/O Line.
Falling Edge
FallingEdge Increment the counter on the falling edge of the selected
I/O Line.
Any Edge
AnyEdge Increment the counter on the falling or rising edge of the
selected I/O Line.
Preliminary