90
•
Operational Reference
Linea Lite GigE Series Camera
PTP Port Last Event
ptpPortLastEvent
Logs the last PTP changed state event defining the last
current status.
Expert
DFNC
None
None
None
Power up
Powerup
Power up
Initialize
Initialize
Initialize
Designated Enabled
DesignatedEnabled
Designated Enabled
Designated Disabled
DesignatedDisabled
Designated Disabled
Fault Cleared
FaultCleared
Fault Cleared
Fault Detected
FaultDetected
Fault Detected
State Decision Event
StateDecisionEvent
State Decision Event
Qualification Timeout
Expires
QualificationTimeoutExpires
Qualification Timeout Expires
Announce Receipt
Timeout Expires
AnnounceReceiptTimeoutExpires
Announce Receipt Timeout Expires
Synchronization Fault
SynchronizationFault
Synchronization Fault
Master Clock Selected
MasterClockSelected
Master Clock Selected
Recommended State
Master
RS_Master
Recommended State Master
Recommended State
Grand Master
RS_GrandMaster
Recommended State Grand Master
Recommended State
Slave
RS_Slave
Recommended State Slave
Recommended State
Passive
RS_Passive
Recommended State Passive
PTP Transport Protocol
ptpTransportProtocol
Describes the PTP Transport Protocol used.
Expert
DFNC
PTP Servo Step Threshold
(in us)
ptpServoStepThreshold
Specifies the servo step threshold (in
μ
s). When the clock
offset with the master exceeds the threshold, the servo
unlocks and offset adjustment is started.
Expert
DFNC
Threshold_10
Threshold_10
10
μ
s threshold.
Threshold_20
Threshold_20
20
μ
s threshold.
Threshold_100
Threshold_100
100
μ
s threshold.
Threshold_500
Threshold_500
500
μ
s threshold.
Threshold_1000
Threshold_1000
1000
μ
s threshold.
Threshold_2000
Threshold_2000
2000
μ
s threshold.
timestampModulo
Specifies the additional interval between the current
timestamp tick and the event generated. This interval has
an 80ns accuracy. Note that the value zero disables the
event generator.
Expert
DFNC
Timestamp Modulo Event
Frequency
timestampModuloFrequency
Returns the frequency of the timestamp Modulo Event (in
Hz).
Expert
DFNC
Timestamp Modulo Start
Time
timestampModuloStartTime
Specifies the timestamp value that must be exceeded by
the incrementing timestamp counter before the modulo
event starts. This Feature is also used for a “Future” Frame
Acquisition.
Expert
DFNC
Timestamp Modulo
Actual
Start Time
timestampModuloActualStartTime Displays the actual modulo event start time as used by the
device. When the user specified
“timestampModuloStartTime” is in the future,
timestampModuloActualStartTime=
timestampModuloStartTime. When the user specified
“timestampModuloStartTime” has a
lready past, the camera
automatically recalculates a future value for
“timestampModuloStartTime” using the user set
“timestampModulo” feature value. This new start time is
reported by “timestampModuloActualStartTime”.
Expert
DFNC
Gev Timestamp Latch
GevtimestampControlLatch
Latch the current timestamp internal counter value in the
timestampValue feature. (WO)
Invisible
Gev Timestamp Value
GevtimestampValue
Returns the 64-bit value of the timestamp counter. (RO)
Invisible
Gev Timestamp Tick
Frequency
GevtimestampTickFrequency
Indicates the number of timestamp ticks (or increments)
during 1 second (frequency in Hz). (RO)
Invisible
Gev Timestamp Reset
GevtimestampControlReset
Resets the timestamp counter to 0. (WO)
Invisible
Preliminary