background image

IDS NXT

IDS Imaging Development Systems GmbH

Dimbacher Str. 10

D-74182 Obersulm, Germany

T: +49 7134 96196-0

E: [email protected]

W: http://www.ids-nxt.com

Technical manual IDS NXT rome

Summary of Contents for NXT rome

Page 1: ...IDS NXT IDS Imaging Development Systems GmbH Dimbacher Str 10 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W http www ids nxt com Technical manual IDS NXT rome...

Page 2: ...al specifications 16 7 1 Pin assignment GigE connector M12 16 7 2 Pin assignment I O connector 17 7 3 Digital input wiring 18 7 4 Digital output wiring 19 7 5 RS 232 wiring 21 8 Status LED 23 9 Optica...

Page 3: ...warranty regulations These contractual warranty regulations are neither extended nor limited by the information contained in this manual Should you require further information on this product or enco...

Page 4: ...ms GmbH Dimbacher Str 10 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W http www ids nxt com Address in UK IDS Imaging Development Systems Ltd Landmark House Station Road RG27 9HA...

Page 5: ...s This symbol indicates hints with useful information for better understanding and using features and functions This symbol indicates important warnings for product safety to prevent damage This symbo...

Page 6: ...otection against electrostatic discharge ESD Board level cameras are especially sensitive to electrostatic discharge Make sure to avoid mechanical or electrical damage of the printed circuit board or...

Page 7: ...fety we recommend using a shielded connection cable or grounding the camera housing so that the camera housing is connected to ground via the appropriate installation Avis pour le Canada Fonctionnemen...

Page 8: ...U WEEE we are obliged to take back this product distributed by us after August 13 2005 free of charge at the end of its useful life and to ensure it correct disposal As this product is exclusively for...

Page 9: ...ified or changed all approval becomes invalid In this case the customer is responsible for ensuring product conformity Product type IDS NXT rome Information for CE EMC specifications EN 61000 6 2 EN 5...

Page 10: ...nt is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmfu...

Page 11: ...s 1 m and the testing period is 30 min Water may not intrude in a quantity which causes harmful effects while the housing is dipped in water under standardized pressure and time conditions Ambient con...

Page 12: ...llowing recommendations apply For a passive heat dissipation mount the camera on a thermally conductive surface like a metal plate or a heat sink If necessary provide an active cooling for example by...

Page 13: ...cables or better for the complete connection between your camera and the host PC The cable length of each segment must not exceed 100 m A segment is a continuous cable connection between two network d...

Page 14: ...test drivers for your network card The transfer rate of GigE network adapters for PCI slots is limited to approximately 110 120 MByte s USB Ethernet adapter can have different restrictions depending o...

Page 15: ...each camera model can be found on our website directly at the respective camera model beneath in the Downloads tab Fig 2 IDS NXT rome NOTICE The camera connectors may be damaged if you install or rem...

Page 16: ...232 wiring 7 1 Pin assignment GigE connector M12 8 pin M12 socket M12 connector MMT361A315 Pin Description Designation 1000BASE T Designation 100BASE TX Fig 3 M12 socket camera rear view 1 MDX0 BI_DA...

Page 17: ...m The maximum length of the I O cable is 30 m The cable must be shielded Power supply NOTICE The camera can be supplied with voltage both from an external source and via Power over Ethernet PoE The ca...

Page 18: ...e found in the model data sheet Keep in mind that a voltage drop will occur when you use long cables for power supply to the camera Choose the size of the cable in such a way that the supply voltage a...

Page 19: ...on voltage VCE SAT 0 03 0 15 V Collector emitter breakdown voltage V BR CE 100 V Collector current continuous IC 150 mA The digital outputs are galvanically isolated using optocouplers to protect the...

Page 20: ...20 IDS NXT Technical manual IDS NXT rome Open collector wiring Fig 6 Wiring as open collector Pin 6 is the reference level GND for all outputs All three outputs can be connected simultaneously as open...

Page 21: ...itter since the load is on pin 6 The other outputs cannot be used anymore 7 5 RS 232 wiring The IDS NXT rome has a serial interface of the type RS 232 Baud rate 300 230 400 Baud Input voltage max 15 V...

Page 22: ...2021 11 08 22 IDS NXT Technical manual IDS NXT rome The data rate of the serial interface depends on the capacity and length of the cable...

Page 23: ...tatus LED 1 camera status two color LED 2 Network status two color LED 1 Camera is off no power Camera is booting Camera is ready Camera is open Camera is ready no valid IP address No firmware loaded...

Page 24: ...e image below Beside the immersion depth also the back focal length has to be considered that means the distance between the last lens and the sensor named bfl in the image below The back focal length...

Page 25: ...glass are absolutely parallel to each other C mount lenses can also be subject to inaccuracies of the flange back distance The tolerance usually is 0 05 mm In some cases however the inaccuracies of c...

Page 26: ...cut filters type DL The filter type is given at the end of the model name The following table shows an overview of the different optical filters used in IDS cameras Filter type Name Refractive index n...

Page 27: ...2021 11 08 27 IDS NXT Technical manual IDS NXT rome Infrared cut filter type HQ Fig 12 HQ filter Plain glass filter typ GL Fig 13 Glass filter...

Page 28: ...asses The filter glasses may only be cleaned from the outside If you remove the glasses the sensor might get soiled IDS Imaging Development Systems GmbH is not liable for any damage to the sensor resu...

Page 29: ...teriorate the optical quality of the glasses Cameras with fixed filter glass Use a wipe to wipe off dirt particles in a single sweep beyond the edge of the filter glass Fig 15 Cleaning fixed filter gl...

Page 30: ...ection User programmable processing on Dual Core ARM Cortex A53 11 1 1 deep ocean core Input data formats Up to 512 x 512 pixels Tensor of shape x y 3 for color Tensor of shape x y 1 for mono Output d...

Page 31: ...rmat output format Single image inference time ms MobileNet V1 1 0 224 224 3 1000 66 MobileNet V1 0 75 224 224 3 1000 50 MobileNet V1 0 5 224 224 3 1000 34 MobileNet V1 0 5 128 128 3 1000 16 MobileNet...

Page 32: ...Housing version 15 I I O connector 17 Immersion depth lens 24 Inference time 30 31 Infrared cut filter 26 Input digital 18 Interface RS 232 21 L Layer count 30 M M12 16 N Network cable 13 card 13 O O...

Reviews: