2021-11-08
12
IDS NXT: Technical manual IDS NXT rome
Non-condensing means that the relative air humidity must be below 100 %. Otherwise, moisture will form on
the camera surface. If, for example, air has a relative humidity of 40 % at 35 °C (95 °F), the relative humidity
will increase to over 100 % if the air cools down to 19.5 °C (67 °F); condensation begins to form.
CAUTION!
As the camera housing may get hot depending on the operating conditions there
may be risk of burns. Provide sufficient heat dissipation so that the housing temperature does
not exceed 55 °C (131 °F).
Notes on ambient conditions
·
Avoid high air humidity levels and rapid temperature changes when using IDS cameras.
·
Temperatures below +4 °C (39 °F) combined with excessive relative air humidity levels can cause icing.
Provide sufficient heat dissipation so that the specified device temperature is not exceeded during operation.
In general, the following recommendations apply:
·
For a passive heat dissipation, mount the camera on a thermally-conductive surface like a metal plate or a
heat sink.
·
If necessary, provide an active cooling for example by means of a fan.
With increasing device temperatures, the image quality could be reduced due to thermal noise. It is
recommended to mount the camera to a heat-dissipating unit even if the camera is operated below the
maximum specified temperature.
Vibration and shock resistance
Vibration and shock resistance of the cameras were tested as specified in EN 60068-2-6 and EN 60068-2-27.
Test parameter EN 60068-2-6 "Environmental testing - Tests: Vibration"
·
Vibration mode: Sinus
·
Lower frequency: 30 Hz
·
Upper frequency: 500 Hz
·
Acceleration: 10 g
·
Throughput speed: 1 octave/minute, logarithmic
·
Number of frequency cycles: 10 per axis
Test parameter EN 60068-2-27 "Environmental testing - Tests: Shock"
·
Shock form: half sine
·
Pulse duration: 1,9 ms
·
Peak acceleration: 80 g
·
Number of shocks per direction: 3 (± X, ±Y, ±Z)
·
Shock form: half sine
·
Pulse duration: 6 ms
·
Peak acceleration: 25 g
·
Number of shocks per direction: 100 (± X, ±Y, ±Z)