Specifications
Si39-504
34
Specifications
Ceiling Mounted Duct Type
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference: 0m.
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference :
0m. (Heat pump only)
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure
means
"High static pressure-Standard".
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its
colorimetric method (gravity method) 50% or more.
6 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
7 Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center. These
values are normally somewhat higher during actual operation as a result of ambient conditions.
Model
FXMQ100MVE
FXMQ125MVE
FXMQ200MVE
FXMQ250MVE
1 Cooling Capacity (19.5°CWB)
kcal/h
10,000
12,500
19,800
24,800
Btu/h
39,600
49,500
78,500
98,300
kW
11.6
14.5
23.0
28.8
2 Cooling Capacity (19.0°CWB)
kW
11.2
14.0
22.4
28.0
3 Heating Capacity
kcal/h
10,800
13,800
21,500
27,100
Btu/h
42,700
54,600
85,300
107,000
kW
12.5
16.0
25.0
31.5
Casing
Galvanized Steel Plate
Galvanized Steel Plate
Galvanized Steel Plate
Galvanized Steel Plate
Dimensions: (H×W×D)
mm
390×1,110×690
390×1,110×690
470×1,380×1,100
470×1,380×1,100
Coil (Cross
Fin Coil)
Rows×Stages×Fin Pitch
mm
3×16×2.0
3×16×2.0
3×26×2.0
3×26×2.0
Face Area
m²
0.319
0.319
0.68
0.68
Fan
Model
2D11/2D3AG1VE
2D11/2D3AF1VE
D13/4G2DA1×2
D13/4G2DA1×2
Type
Sirocco Fan
Sirocco Fan
Sirocco Fan
Sirocco Fan
Motor Output × Number
of Units
W
270×1
430×1
380×2
380×2
Air Flow Rate (H/L)
m³/min
29/23
36/29
58/50
72/62
cfm
1,024/812
1,271/1,024
2,047/1,765
2,542/2,189
External Static
Pressure 50 / 60Hz
Pa
157/172-98/98 4
191/245-152/172 4
221/270-132 4
270/191-147 4
Drive
Direct Drive
Direct Drive
Direct Drive
Direct Drive
Temperature Control
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Sound Absorbing Thermal Insulation Material
Glass Fiber
Glass Fiber
Glass Fiber
Glass Fiber
Air Filter
5
5
5
5
Piping
Connections
Liquid Pipes
mm
φ
9.5 (Flare Connection)
φ
9.5 (Flare Connection)
φ
9.5 (Flare Connection)
φ
9.5 (Flare Connection)
Gas Pipes
mm
φ
15.9 (Flare Connection)
φ
15.9 (Flare Connection)
φ
19.1(Brazing Connection)
φ
22.2 (Brazing Connection)
Drain Pipe
mm
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
PS1B
PS1B
Machine Weight (Mass)
kg
63
65
137
137
7 Sound Level (H/L) (220V)
dBA
43/39
45/42
48/45
48/45
Safety Devices
Fuse,
Thermal Fuse for Fan Motor
Fuse,
Thermal Fuse for Fan Motor
Fuse,
Thermal Protector for Fan
Motor
Fuse,
Thermal Protector for Fan
Motor
Refrigerant Control
Electronic Expansion Valve
Electronic Expansion Valve
Electronic Expansion Valve
Electronic Expansion Valve
Connectable outdoor unit
R-410A M(A) Series
R-410A M(A) Series
R-410A M(A) Series
R-410A M(A) Series
Standard Accessories
Operation Manual,
Installation Manual, Drain
Hose, Clamp Metal,
Insulation for Fitting, Sealing
Pads, Clamps, Screws.
Operation Manual,
Installation Manual, Drain
Hose, Clamp Metal,
Insulation for Fitting, Sealing
Pads, Clamps, Screws.
Operation Manual,
Installation Manual, Sealing
Pads, Connection Pipes,
Screws, Clamps.
Operation Manual,
Installation Manual, Sealing
Pads, Connection Pipes,
Screws, Clamps.
Drawing No.
C : 3D038814
(
)
(
)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
Summary of Contents for VRV II RXYQ5MATL
Page 53: ...Specifications Si39 504 42 Specifications...
Page 115: ...Outline of Control Indoor Unit Si39 504 104 Function...
Page 161: ...Field Setting Si39 504 150 Test Operation...
Page 172: ...Si39 504 Troubleshooting by Remote Controller Troubleshooting 161...
Page 266: ...Si39 504 Piping Diagrams Appendix 255 RXYQ8MA 10MA 12MAYL E TL E 3D048033A...
Page 267: ...Piping Diagrams Si39 504 256 Appendix RXYQ14MA 16MAYL E TL E 3D048034A...
Page 271: ...Wiring Diagrams for Reference Si39 504 260 Appendix RXYQ8MA 10MA 12MAYL E 3D047088C...
Page 272: ...Si39 504 Wiring Diagrams for Reference Appendix 261 RXYQ14MA 16MAYL E 3D047089C...
Page 273: ...Wiring Diagrams for Reference Si39 504 262 Appendix 2 1 2 RXYQ MATL E RXYQ5MATL E 3D049059A...
Page 274: ...Si39 504 Wiring Diagrams for Reference Appendix 263 RXYQ8MA 10MA 12MATL E 3D049060A...
Page 275: ...Wiring Diagrams for Reference Si39 504 264 Appendix RXYQ14MA 16MATL E 3D049061A...
Page 283: ...Wiring Diagrams for Reference Si39 504 272 Appendix FXCQ40M 50M 80M 125MVE 3D039557A...
Page 285: ...Wiring Diagrams for Reference Si39 504 274 Appendix FXKQ25M 32M 40M 63MVE 3D039564B...
Page 289: ...Wiring Diagrams for Reference Si39 504 278 Appendix FXMQ40M 50M 63M 80M 100M 125MVE 3D039620B...
Page 290: ...Si39 504 Wiring Diagrams for Reference Appendix 279 FXMQ200M 250MVE 3D039621B...
Page 291: ...Wiring Diagrams for Reference Si39 504 280 Appendix FXHQ32M 63M 100MVE 3D039801D...
Page 292: ...Si39 504 Wiring Diagrams for Reference Appendix 281 FXAQ20M 25M 32MVE 40M 50M 63MVE 3D034206C...
Page 309: ...Selection of Pipe Size Joints and Header Si39 504 298 Appendix Note 1...
Page 315: ...Method of Replacing The Inverter s Power Transistors and Diode Modules Si39 504 304 Appendix...