Option List
Si39-504
292
Appendix
4.
Option List
4.1
Option List of Controllers
Operation Control System Optional Accessories
Note:
1. Installation box (No.8) is necessary for each adaptor marked .
2. Up to 2 adaptors can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box (No. 8) is necessary for second adaptor.
6. Installation box (No. 8) is necessary for each adaptor.
7. This adaptor is required when connecting with optional controller for centralized control.
8. BRC2A51 is also available.
Various PC Boards
System Configuration
Note:
Installation box for adaptor must be procured on site.
No.
Type
FXCQ-M
FXFQ-M
FXKQ-M
FXDQ-N
FXSQ-M
FXMQ-M
FXHQ-M
FXAQ-M
FXLQ-M
FXNQ-M
Item
1
Remote
controller
Wireless
BRC7C62
BRC7E61W
BRC4C61
BRC4C62
BRC4C62
BRC7E63W
BRC7E618
BRC4C62
Wired
BRC1A61
BRC1A62
BRC1A62
BRC1A61
BRC1A62
2
Wired remote controller
with weekly schedule timer
BRC1D61
3
Simplified remote
controller
—
Note 8
BRC2C51
Note 8
BRC2C51
—
Note 8
BRC2C51
4
Remote controller for
hotel use
—
BRC3A61
BRC3A61
—
BRC3A61
5
Adaptor for wiring
KRP1B61
KRP1B59
KRP1B61
KRP1B56
KRP1B61
KRP1B3
—
KRP1B61
6-1
Wiring adaptor for
electrical appendices (1)
KRP2A61
KRP2A62
KRP2A61
KRP2A53
KRP2A61
KRP2A62
KRP2A61
KRP2A61
6-2
Wiring adaptor for
electrical appendices (2)
KRP4A51
KRP4A53
KRP4A51
KRP4A54
KRP4A51
KRP4A52
KRP4A51
KRP4A51
7
Remote sensor
KRCS01-1
—
KRCS01-1
8
Installation box for
adaptor PC board
Note 2, 3
KRP1B96
Note 2, 3
KRP1D98
—
Note 4, 6
KRP1B101
Note 5
KRP4A91
—
Note 3
KRP1C93
Note 2, 3
KRP4A93
—
9
Central remote controller
DCS302C(A)61
9-1
Electrical box with earth
terminal (3 blocks)
KJB311A
10
Unified on/off controller
DCS301B(A)61
10-1
Electrical box with earth
terminal (2 blocks)
KJB212A
10-2
Noise filter (for
electromagnetic interface
use only)
KEK26-1
11
Schedule timer
DST301B(A)61
12
External control adaptor
for outdoor unit (Must be
installed on indoor units)
DTA104A61
DTA104A62
DTA104A61
DTA104A53
DTA104A61
DTA104A62
DTA104A61
DTA104A61
13
Interface adaptor for
SkyAir-series
—
—
—
—
—
—
—
—
No.
Part name
Model No.
Function
1
Adaptor for wiring
KRP1B56
KRP1B57
KRP1B59
KRP1B61
KRP1B3
PC board when equipped with auxiliary electric heater in the indoor unit.
2
DIII-NET Expander Adaptor
DTA109A51
Up to 1024 units can be centrally controlled in 64 different groups.
Wiring restrictions (max. length: 1000m, total wiring length: 2000m, max. number of
branches: 16) apply to each adaptor.
No.
Part name
Model No.
Function
1
Central remote controller
DCS302C(A)61
Up to 64 groups of indoor units (128 units)can be connected, and ON/OFF, temperature
setting and monitoring can be accomplished individually or simultaneously. Connectable up
to “2” controllers in one system.
2
Unified ON/OFF controller
DCS301B(A)61
Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or
simultaneously, and operation and malfunction can be displayed. Can be used in
combination with up to 8 controllers.
3
Schedule timer
DST301B(A)61
Programmed time weekly schedule can be controlled by unified control for up to 64 groups
of indoor units (128 units). Can turn units ON/OFF twice per day.
4
Unification adaptor for computerized
control
DCS302A52
Interface between the central monitoring board and central control units
5
Interface adaptor for SkyAir-series
DTA102A52
Adaptors required to connect products other than those of the VRV System to the high-
speed DIII-NET communication system adopted for the VRV System.
To use any of the above optional controllers, an appropriate adaptor must be installed on
the product unit to be controlled.
6
Central control adaptor kit
DTA107A55
7
Wiring adaptor for other air-conditioner
DTA103A51
8
DIII-NET
Expander adaptor
DTA109A51
Up to 1,024 units can be centrally controlled in 64 different groups.
Wiring restrictions (max. length : 1,000m, total wiring length : 2,000m, max. number of
branches : 16) apply to each adaptor.
9
Mounting plate
KRP4A92
Fixing plate for DTA109A51
Summary of Contents for VRV II RXYQ5MATL
Page 53: ...Specifications Si39 504 42 Specifications...
Page 115: ...Outline of Control Indoor Unit Si39 504 104 Function...
Page 161: ...Field Setting Si39 504 150 Test Operation...
Page 172: ...Si39 504 Troubleshooting by Remote Controller Troubleshooting 161...
Page 266: ...Si39 504 Piping Diagrams Appendix 255 RXYQ8MA 10MA 12MAYL E TL E 3D048033A...
Page 267: ...Piping Diagrams Si39 504 256 Appendix RXYQ14MA 16MAYL E TL E 3D048034A...
Page 271: ...Wiring Diagrams for Reference Si39 504 260 Appendix RXYQ8MA 10MA 12MAYL E 3D047088C...
Page 272: ...Si39 504 Wiring Diagrams for Reference Appendix 261 RXYQ14MA 16MAYL E 3D047089C...
Page 273: ...Wiring Diagrams for Reference Si39 504 262 Appendix 2 1 2 RXYQ MATL E RXYQ5MATL E 3D049059A...
Page 274: ...Si39 504 Wiring Diagrams for Reference Appendix 263 RXYQ8MA 10MA 12MATL E 3D049060A...
Page 275: ...Wiring Diagrams for Reference Si39 504 264 Appendix RXYQ14MA 16MATL E 3D049061A...
Page 283: ...Wiring Diagrams for Reference Si39 504 272 Appendix FXCQ40M 50M 80M 125MVE 3D039557A...
Page 285: ...Wiring Diagrams for Reference Si39 504 274 Appendix FXKQ25M 32M 40M 63MVE 3D039564B...
Page 289: ...Wiring Diagrams for Reference Si39 504 278 Appendix FXMQ40M 50M 63M 80M 100M 125MVE 3D039620B...
Page 290: ...Si39 504 Wiring Diagrams for Reference Appendix 279 FXMQ200M 250MVE 3D039621B...
Page 291: ...Wiring Diagrams for Reference Si39 504 280 Appendix FXHQ32M 63M 100MVE 3D039801D...
Page 292: ...Si39 504 Wiring Diagrams for Reference Appendix 281 FXAQ20M 25M 32MVE 40M 50M 63MVE 3D034206C...
Page 309: ...Selection of Pipe Size Joints and Header Si39 504 298 Appendix Note 1...
Page 315: ...Method of Replacing The Inverter s Power Transistors and Diode Modules Si39 504 304 Appendix...