CTXS-J, CTXS-H, FTXS-H Series
Operation Manual
86
2.9
Note for Multi System
1. With the priority room setting present but
inactive or not present.
When more than one indoor unit is operating, priority is
given to the first unit that was turned on.
In this case, set the units that are turned on later to the
same operation mode (*1) as the first unit.
Otherwise, they will enter the standby state, and the
OPERATION lamp will flash: this does not indicate malfunction.
(*1)
• COOL, DRY and FAN operation may be used at the same time.
• AUTO operation automatically selects COOL operation or HEAT operation based on the room temperature.
Therefore, AUTO operation is available when selecting the same operation mode as that of the room with the first unit to be
turned on.
This system has one outdoor unit connected to multiple
indoor units.
Note for Multi System
What is a multi system?
Selecting the operation mode
NIGHT QUIET mode (Available only for COOL operation)
CAUTION
• Normally, the operation mode in the room where the unit is first run is given priority, but the following situations are exceptions, so please
keep this in mind.
If the operation mode of the first room is FAN operation, then using HEAT operation in any room after this will give priority to HEAT operation.
In this situation, the air conditioner running in FAN operation will go on standby, and the OPERATION lamp will flash.
NIGHT QUIET mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the nighttime hours to prevent annoyance to neighbors.
• The NIGHT QUIET mode is activated when the temperature drops 9
°
F (5
°
C) or more below the highest temperature recorded
that day. Therefore, when the temperature difference is less than 9
°
F (5
°
C), this function will not be activated.
• NIGHT QUIET mode reduces slightly the cooling efficiency of the unit.
2. With the priority room setting active.
See priority room setting on the next page.
Outdoor
unit
A
room
B
room