SiUS12-928_B
Check
Service Diagnosis
200
7.14 Capacitor Voltage Check
Check No.21
Before this check, be sure to check the main circuit for short circuit.
With the circuit breaker still on, measure the voltage according to the drawing of the model in
question. Be careful never to touch any live parts.
18 class
24/32 class
TB2
>PS<
TB3
P2
N1
S90
S92
S93
S80
S20
S21 S22
S40
(R11308)
Multimeter
(DC. voltage range)
(R12869)
Multimeter
(DC. voltage range)