Indoor Unit
SiUS12-928_B
19
Printed Circuit Board Connector Wiring Diagram
1.2
CTXS07LVJU, FTXS09/12LVJU
Connectors and
Other Parts
PCB (1): Control PCB
PCB (2): Signal Receiver PCB
PCB (3): Display PCB
PCB (4): INTELLIGENT EYE Sensor PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than JA, JB, and JC.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S1
Connector for DC fan motor
2) S21
Connector for centralized control (HA)
3) S25
Connector for INTELLIGENT EYE sensor PCB
4) S32
Indoor heat exchanger thermistor
5) S41
Connector for swing motors
6) S46
Connector for display PCB
7) S47
Connector for signal receiver PCB
8) H1, H2, H3, FG
Connector for terminal board
9) JA
Address setting jumper
Refer to page 265 for detail.
10)JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
Refer to page 266 for detail.
11)LED A
LED for service monitor (green)
12)FU1 (F1U)
Fuse (3.15 A, 250 V)
13)V1
Varistor
1) S48
Connector for control PCB
1) S49
Connector for control PCB
2) SW1
Forced operation [ON/OFF] button
3) LED1 (H1P)
LED for operation (green)
4) LED2 (H2P)
LED for timer (yellow)
5) LED3 (H3P)
LED for INTELLIGENT EYE (green)
6) RTH1 (R1T)
Room temperature thermistor
1) S26
Connector for control PCB