![background image](http://html1.mh-extra.com/html/daikin/stylish-series/stylish-series_service-manual_2459098117.webp)
2
|
Components
Service manual
117
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
c
a
b
a
Fan guard
b
Rocker arm
c
Swing raster
4
Remove the 3 screws from the swing flap motor gear case assembly. Do NOT
yet remove the assembly from the indoor unit.
a
a
b
a
a
Screw
b
Swing flap motor gearcase assembly
5
Disconnect the rocker arm from the swing raster.
6
Remove the swing flap motor gear case assembly from the indoor unit.
7
Disconnect the harness from the swing flap motor.
8
Disconnect the harness from the swing raster motor.
9
To install the swing flap motor gearcase assembly, see
116].
To install the swing flap motor gearcase assembly
1
Connect the harness to the swing raster motor connector.
2
Install the swing flap motor gearcase assembly on the indoor unit. Install the 3
screws, but do NOT yet tighten them.