![background image](http://html1.mh-extra.com/html/daikin/stylish-series/stylish-series_service-manual_2459098109.webp)
2
|
Components
Service manual
109
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
To re-install the front grille
1
Install the front grille and firmly engage the 3 upper hooks.
2
Tighten the 2 screws and put the 2 screw covers back.
3
Re-install the flap.
4
Insert the wire harness back into the connector and secure it with the wire
clamp.
5
Close the front panel. Refer to
106].
To remove the electrical wiring box cover
1
Remove the front grille.
2
Remove 1 screw from the electrical wiring box.
3
Open the electrical wiring box cover by pulling it to the front.
4
Remove the electrical wiring box cover from the 2 rear hooks.
1
2
b
a
c
c
a
Screw
b
Electrical wiring box
c
Rear hook
5
To re-install the cover, first attach the electrical wiring box to the hooks, close
the electrical wiring box, and re-install the screw.
2.14 Reactor
2.14.1 Checking procedures
To perform an electrical check of the reactor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
2
Open the compressor insulation.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
3
Remove the cover of the compressor wire terminals.
Summary of Contents for Stylish Series