2
|
Components
Service manual
124
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
c
a
b
e
d
f
f
a
Clip
b
Thermistor
c
Thermistor holder
d
Insulation
e
Thermistor wire
f
Tie strap
2
Connect the thermistor connector to the appropriate PCB.
INFORMATION
Some of the thermistors are wired to the same connector. See connector and pin
information of the thermistors at the start of the electrical check procedure and
145]. ALWAYS replace the complete set of thermistors wired
to the same connector.
3
When installing the complete set of thermistors wired to the same connector:
▪
Install all other thermistors wired to the connector in their thermistor
holder,
▪
Route the thermistor harness of all thermistors towards the appropriate
PCB,
▪
Connect the thermistor connector to the appropriate PCB.