![background image](http://html1.mh-extra.com/html/daikin/stylish-series/stylish-series_service-manual_2459098100.webp)
2
|
Components
Service manual
100
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
To remove the top plate
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Loosen and remove the screws that fix the top plate.
a
b
a
a
a
a
a
a
Screw
b
Top plate
2
Remove the top plate.
To remove the front plate
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
1
Loosen and remove the screws that fix the front plate.
a
a
a
a
a
a
a
Screw
b
Front plate
2
Remove the front plate.
To remove the compressor sound insulation
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
Remove the front plate, see
99].
1
Untwist the cord and remove the compressor sound insulation.