![background image](http://html1.mh-extra.com/html/daikin/stylish-series/stylish-series_service-manual_2459098114.webp)
2
|
Components
Service manual
114
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
2
Measure the resistance between the following pins of the motor connector.
The measurements MUST be as shown in the table below.
Pins
Measured resistance (Ω)
1-2
235
1-3
1-4
1-5
2-3
470
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Action
Yes
Return to the troubleshooting of the
specific error and continue with the
next procedure.
No
Replace the swing flap motor, see
114].
Repair procedures
INFORMATION
To replace the motor, the complete gearcase assembly MUST be replaced.
To remove the swing flap motor gearcase assembly
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Remove the main swing flap from the indoor unit (by clicking it out).
2
Remove the 2 screws and remove the swing flap motor gearcase assembly
from the indoor unit.