2.15 Streamer unit
2.15.1 Checking procedures
1
As there is no specific check procedure for this component, first perform a
check of the indoor unit PCB to check if the streamer unit needs to be
replaced. See
After complete check of the indoor unit
PCB, is the problem solved?
Action
Yes
No further actions required.
No
Replace the streamer unit, see
2.15.2 Repair procedures
To remove the streamer unit
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect the streamer unit connector from the indoor unit PCB.
a
b
c
c
a
Streamer unit connector
b
Streamer unit
c
Retainer
2
Route the streamer unit harness out of the retainers.
3
Click the streamer unit out of the indoor unit.