ESIE04-01
Disassembly and Maintenance: Indoor Units
Part 5 – Disassembly and Maintenance
5–25
3
5
1
5
Components
The table below contains the components of the exploded view.
No.
Component
No.
Component
1
Top plate assy
29
Plain washer
2
Right plate assy
30
Fitting bolt drain pump
3
Left plate assy
31
Fan assy
4
Interchangeable plate
31.1
Fan top plate
5
Small bottom plate
31.2
Fan housing bottom
6
Large bottom plate
31.3
Fan housing top
7
Air outlet flange
31.4
Rotor assy
8
Center stay assy
31.4.1
Hexagon socket screw (FBQ60)
9
Air filter holding plate assy
31.5
Fan motor
10
Stay for fan top panel assy
31.6
Fan motor stand
11
Fan side blind plate assy
31.7
Motor fixing plate assy
12
Cooler side blind plate assy
32
Switch box assy
13
Pipe setting plate assy
32.1
Switch box body
14
Swtich box cover assy
32.2
Switch box fixing plate
15
Drain pan setting plate
32.3
Terminal fixing plate
16
Drain socket cover assy 1
32.4
Option fixing plate left
17
Drain socket cover assy 2
32.5
Option fixing plate right
18
Hanger bracket
32.6
PCB assy
19
Drain pan assy
32.7
Air thermistor
19.1
Drain socket cap
32.8
Power supply transformer
20
Heat exchanger assy
32.9
Fan motor capacitor
20.1
Distributor with filter assy
32.10
Terminal for remote controller
20.2
Single union joint
32.11
Terminal for power supply
20.3
Single union joint
32.12
Wire harness
20.4
Flare nut
32.13
Wire harness
20.5
Flare nut
32.14
Tie wrap with clip
21
Air filter assy
32.15
Capacity setting adaptor (FBQ60)
22
Service cover assy
33
Thermistor (liquid)
23
Drain pump fixing plate
34
Thermistor (coil) (FBQ60)
24
Service cover cap assy
35
Thermistor fixing blade
25
Drain pump
36
Metal clamp
26
Float switch
37
Drain hose
27
Drain hose assy
38
Insulation for joint (gas)
28
Vibration absorber
39
Insulation for joint (liquid)
RZQ - Final.book Page 25 Wednesday, September 8, 2004 8:40 AM
Summary of Contents for RZQ71~125B7V3B
Page 1: ...Service Manual ESIE04 01 RZQ71 125B7V3B Sky Air Inverter R 410A B series ...
Page 2: ......
Page 24: ...ESIE04 01 1 2 Part 1 System Outline 3 1 1 5 ...
Page 32: ...General Outline Outdoor Units ESIE04 01 1 10 Part 1 System Outline 3 1 1 4 5 ...
Page 64: ...General Outline Indoor Units ESIE04 01 1 42 Part 1 System Outline 3 1 1 4 5 ...
Page 76: ...Specifications ESIE04 01 1 54 Part 1 System Outline 3 1 1 4 5 ...
Page 92: ...Functional Diagrams ESIE04 01 1 70 Part 1 System Outline 3 1 1 4 5 ...
Page 94: ...ESIE04 01 1 72 Part 1 System Outline ...
Page 122: ...Wiring Diagrams ESIE04 01 1 100 Part 1 System Outline 3 1 1 4 5 ...
Page 140: ...ESIE04 01 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 162: ...General Functionality ESIE04 01 2 24 Part 2 Functional Description 3 1 2 4 5 ...
Page 200: ...Outdoor Unit Functional Concept ESIE04 01 2 62 Part 2 Functional Description 3 1 2 4 5 ...
Page 202: ...ESIE04 01 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 288: ...Error Codes Outdoor Units ESIE04 01 3 88 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 312: ...Additional Checks for Troubleshooting ESIE04 01 3 112 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 314: ...ESIE04 01 4 2 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 356: ...ESIE04 01 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...
Page 484: ...ESIE04 01 viii Index 3 1 4 5 ...