Introduction
ESIE04-01
ii
3
1
4
5
1.2
Combination Overview
Introduction
In the tables in this section:
P
“2” stands for twin combination.
P
“3” stands for triple combination.
P
“4“ double twin combination.
P
“P” and “M” are allowed and guaranteed combinations, but they will not be officially mentioned as
such in catalogues or databooks.
FCQ, FFQ, FBQ
The table below contains the possible combinations between indoor units (FCQ, FFQ and FBQ) and
outdoor units of the Sky Air RZQ-series.
FDQ, FHQ, FUQ,
FAQ
The table below contains the possible combinations between indoor units (FDQ, FHQ, FUQ and FAQ)
and outdoor units of the Sky Air RZQ-series.
950 x 950 Cassette
600 x 600 Cas.
Duct
F
C
Q
35B7V
1
F
C
Q
50B7V
1
F
C
Q
60B7V
1
F
C
Q
71B7V
3B
F
C
Q
100B7V
3B
F
C
Q
125B7V
3B
F
F
Q
25B
V1B
F
F
Q
35B
V1B
F
F
Q
50B
V1B
F
F
Q
60B
V1B
F
B
Q
25B7
V
1
F
B
Q
35B7
V
1
F
B
Q
50B7
V
1
F
B
Q
60B7
V
1
F
B
Q
71B7
V
3B
F
B
Q
100B
7V3B
F
B
Q
125B
7V3B
RZQ71B7V3B
2
–
–
P
–
–
–
2
–
–
–
2
–
–
P
–
–
RZQ100B7V3B
3
2
–
–
P
–
–
3
2
–
–
3
2
–
–
P
–
RZQ125B7V3B
4
3
2
–
–
P
–
4
3
2
–
4
3
2
–
–
P
Outdoor unit
Indoor unit
LD
Ceiling suspended
C.S. Cas.
Wall
F
D
Q
125B
7V3B
F
H
Q
35B
UV1
F
H
Q
50B
UV1
F
H
Q
60B
UV1
F
H
Q
71B
UV1B
F
H
Q
100B
UV1
B
F
H
Q
125B
UV1
B
F
U
Q
71B
UV1B
F
U
Q
100B
UV1
B
F
U
Q
125B
UV1
B
F
A
Q
71B
UV1B
F
A
Q
100B
UV1B
RZQ71B7V3B
–
2
–
–
P
–
–
P
–
–
P
–
RZQ100B7V3B
–
3
2
–
–
P
–
–
P
–
–
P
RZQ125B7V3B
P
4
3
2
–
–
P
–
–
P
–
–
Outdoor unit
Indoor unit
RZQ - Final.book Page ii Wednesday, September 8, 2004 8:40 AM
Summary of Contents for RZQ71~125B7V3B
Page 1: ...Service Manual ESIE04 01 RZQ71 125B7V3B Sky Air Inverter R 410A B series ...
Page 2: ......
Page 24: ...ESIE04 01 1 2 Part 1 System Outline 3 1 1 5 ...
Page 32: ...General Outline Outdoor Units ESIE04 01 1 10 Part 1 System Outline 3 1 1 4 5 ...
Page 64: ...General Outline Indoor Units ESIE04 01 1 42 Part 1 System Outline 3 1 1 4 5 ...
Page 76: ...Specifications ESIE04 01 1 54 Part 1 System Outline 3 1 1 4 5 ...
Page 92: ...Functional Diagrams ESIE04 01 1 70 Part 1 System Outline 3 1 1 4 5 ...
Page 94: ...ESIE04 01 1 72 Part 1 System Outline ...
Page 122: ...Wiring Diagrams ESIE04 01 1 100 Part 1 System Outline 3 1 1 4 5 ...
Page 140: ...ESIE04 01 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 162: ...General Functionality ESIE04 01 2 24 Part 2 Functional Description 3 1 2 4 5 ...
Page 200: ...Outdoor Unit Functional Concept ESIE04 01 2 62 Part 2 Functional Description 3 1 2 4 5 ...
Page 202: ...ESIE04 01 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 288: ...Error Codes Outdoor Units ESIE04 01 3 88 Part 3 Troubleshooting 3 1 3 4 5 ...