ESIE04-01
Troubleshooting
Part 3 – Troubleshooting
3–31
3
3
4
5
1
P
In the case of the shaded error codes, “inspection” is not displayed. The system operates, but be
sure to inspect and repair it.
Notes:
1
There is a possibility of open phase power supply, check power supply also.
2
Operation when a malfunction occurs may differ according to the model.
P1
Open phase or voltage unbalance
P4
Abnormal radiation fin temperature sensor
(outdoor unit)
PJ
Failure of capacity setting (outdoor unit)
Either capacity data is set incorrectly, or capacity
has not been set for the data IC
U0
Lack of gas malfunction
Abnormal suction pipe temperature
U2
Abnormal power supply voltage
Including malfunction of K1M, K2M
U4/UF
Failure of transmission (between indoor and
outdoor unit)
Transmission between indoor and outdoor unit is
not being correctly carried out. (Note 1, Note 2)
U5
Failure of transmission (between indoor unit and
remote controller)
Transmission between indoor and remote
controller is not being correctly carried out.
U8
Failure of transmission (between “main” and
“sub” remote controller
Transmission between “main” and “sub” remote
controller is not being correctly carried out.
UA
Failure of fieldsetting
System fieldsetting error pair, twin, triple, double
twin or wrong capacity class.
UC
Address error of central remote controller
Malfunction Code
Contents/Processing
Remarks
RZQ - Final.book Page 31 Wednesday, September 8, 2004 8:40 AM
Summary of Contents for RZQ71~125B7V3B
Page 1: ...Service Manual ESIE04 01 RZQ71 125B7V3B Sky Air Inverter R 410A B series ...
Page 2: ......
Page 24: ...ESIE04 01 1 2 Part 1 System Outline 3 1 1 5 ...
Page 32: ...General Outline Outdoor Units ESIE04 01 1 10 Part 1 System Outline 3 1 1 4 5 ...
Page 64: ...General Outline Indoor Units ESIE04 01 1 42 Part 1 System Outline 3 1 1 4 5 ...
Page 76: ...Specifications ESIE04 01 1 54 Part 1 System Outline 3 1 1 4 5 ...
Page 92: ...Functional Diagrams ESIE04 01 1 70 Part 1 System Outline 3 1 1 4 5 ...
Page 94: ...ESIE04 01 1 72 Part 1 System Outline ...
Page 122: ...Wiring Diagrams ESIE04 01 1 100 Part 1 System Outline 3 1 1 4 5 ...
Page 140: ...ESIE04 01 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 162: ...General Functionality ESIE04 01 2 24 Part 2 Functional Description 3 1 2 4 5 ...
Page 200: ...Outdoor Unit Functional Concept ESIE04 01 2 62 Part 2 Functional Description 3 1 2 4 5 ...
Page 202: ...ESIE04 01 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 288: ...Error Codes Outdoor Units ESIE04 01 3 88 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 312: ...Additional Checks for Troubleshooting ESIE04 01 3 112 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 314: ...ESIE04 01 4 2 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 356: ...ESIE04 01 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...
Page 484: ...ESIE04 01 viii Index 3 1 4 5 ...