![background image](http://html1.mh-extra.com/html/daikin/rxq25amv1b/rxq25amv1b_service-manual_4205016102.webp)
3
|
Components
Service manual
102
RXQ25+3 3 3
35AMV1B
Split Sensira R32 BBOP
ESIE21-16 – 2022.02
5
Place both hands under the centre of the front grille, push it up and then
toward you.
1
2
To remove the electrical wiring box cover
TO OPEN THE SERVICE COVER
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite:
Remove the front grille.
1
Remove 1 screw from the electrical wiring box.
2
Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
3
Unhook the tab(s) on the bottom and remove the electrical wiring box cover.
c
b
b
a
a
1
1
3
2
a
Tab
b
Protruding part on the top of the cover
c
Screw