3-38
(9) Replace the old controller with the new one.
Tilt the controller unit to take it out from or insert it into the control box. (Refer to the figure below.)
→
Prevent the corner of the controller from damaging the harness or other parts.
(10) Fix the new controller with mounting screw (with washer)
!7
, mounting screw
!8
, spring washer
!9
and toothed lock washer
@0
.
→
Ensure that the mounting screw, spring washer and toothed lock washer are installed in correct
places.
→
Tighten the screws securely and completely.
(11) Insert connectors
!4
to
!6
into the CPU board and power supply I/O board.
(12) Fix the harness of connector
!2
to wire saddle
r
and pass it behind the harness bundle. (Refer to
the figure below.)
Insert connector
!2
into the PT/CT board, and fix the harness to clamp
!3
.
→
When fixing the harness to the clamp, ensure that the sheet metal is not touched with the
harness being stretched.
(13) Fix dry cell battery or rechargeable battery
!1
with Velcro tape
!0
.
(14) Fix the harness of connector
i
to wire saddle
r
, and insert connector
i
.
(15) Insert connector
y
into the CPU board, and fix the harness to clamp
u
.
→
When fixing the harness to the clamp, ensure that the sheet metal is not touched with the
harness being stretched.
Attention (When inserting each connector)
●
Do not directly touch the CPU board and power supply I/O board.
●
Do not apply excessive load to the CPU board and power supply I/O board.
●
Insert the connector securely by confirming its shape, direction, number of pins and color.
→
Otherwise, the connection may not function normally, proper connection may not be
established, the board may be broken, or the connector may be lost during the transportation.
Clamp
!3
Harness bundle
03̲LXE10E100以降(33-41)̲E.qx 08.8.22 10:31 AM ページ 3-38