3-36
3.6 Information interchange with personal computer
The electronic controller DECOS
3
e has a internal memory function to record the set point temperature,
inside temperature, operation mode, occurrence alarm and the report of automatic PTI during
transportation in addition to the normal operation control.
Also users can retrieve the logging data and operations condition of the unit and save the information on a
personal computer through the serial communication port (personal computer receptacle) provided on the
controller front panel. The retrieved data are useful to analyze any problems that occurred during
transportation and to prepare various kinds of reports.
Moreover, users can up-load the information such as the container No., cargo name, destination and other
information from their personal computer to the controller.
Refer to the Operation Manual for Personal Computer Software for detail.
Logged data can be retrieved with the aid of personal computer software.
Refer to the Operation Manual for Personal Computer Software for detail.
3.6.1 Data logging
The data logging function is to store operation data which is generated during navigation.
There are seven kinds of logging data.
As to Tripdata, its logging interval can select from 15, 30, 60 (default) and 120 minutes.
※
When F. PTI is executed, the logging interval become default (Refer to clause 3.8.2.3)
※
Controller has Max. 2 years capacity at 60 min log interval.
Type
Logging data
1
ID data
¡
Setting temperature
¡
Setting ventilation amount
¡
Setting humidity
2
Trip data
¡
Operation date (year, month, day)
¡
Outside air temperature
¡
Operation time
¡
Setting humidity (Optional)
¡
Setting temperature
¡
Humidity (Optional)
¡
Supply air temperature for data recorder
¡
Operation mode
¡
Discharge air temperature for data recorder
¡
Supply air temperature
¡
Discharge air temperature
3
USDA
¡
Pulp temperature sensor USDA #1 to #3
(Optional)
¡
Year/month/day/time
¡
Logging interval of 1 hour
4
USDA+CTS
¡
Pulp temperature sensor USDA #1 to #3
(Optional)
¡
Cargo temperature sensor CTS
¡
Year/month/day/time
¡
Logging interval of 1 hour
5
Event
¡
Power ON/OFF
¡
Defrosting interval setting change
¡
Unit ON/OFF
¡
Defrosting IN/OUT
¡
Setting temperature change
¡
PTI startup and result
¡
Setting humidity change
¡
Battery mode startup
6
Alarm
¡
Alarm occurrence date (year/month/day)
¡
Alarm code
7
PTI
¡
SHORT PTI
¡
FULL PTI
8
Software
¡
Version of the software installed in the controller
version
9
Controller
Serial number of the controller
serial number
03̲LXE10E100以降(33-41)̲E.qx 08.8.22 10:31 AM ページ 3-36