3-20
10. OPTIONAL FUNCTION SETTING MODE
<Key operation to enter/exit>
<Key operation in this mode>
Whenever the
key is pressed, the display changes.
For the determination of setting, turn the power breaker OFF after the setting.
S
I/O ON
F. PTI
S. PTI
M. CHECK
※
11
※
12
※
13
Power off
Unit off
All Lighting
(for 3 sec.)
Preparation
(for 18 sec.)
Current
indication
※
1
Circuit Breaker ON
for 3 sec.
for 3 sec.
for 3 sec.
for 3 sec.
for 3 sec.
I/O
Circuit Breaker OFF
after setting change
(
OFF when no setting changed
)
Optional
Function
Setting
Basic
Function
Setting
Optional
Condition
Setting
Input
Data
※
10
LED screen
LCD screen
Setting method
Indications or setting items
OFF: USDA sensor not available
3
: 3 USDA sensors
4
: 3 USDA sensors and 1
cargo temperature sensor
Au : The numbers of USDA
sensors and cargo sensors
are automatically detected and
set.
ON
: If the dehumidification sensor
is provided and the
dehumidification function is
available
ON-A: If the dehumidification sensor
is not provided but the
dehumidification function is
available
OFF
: If the dehumidification
function is not available
Note
: Either "ON" or "ON-A" is
displayed depending on the
model.
Make selection using the key
and key. Press the key
to determine the selection.
Note: "3" is set automatically if
2 USDA sensors are
connected.
Make selection using the key
and key. Press the key
to determine the selection.
Note: The dehumidification can
be turned ON and OFF
during the mode operation
described in 3.3.4.
USdA
dHU
S
S
USDA sensor available/
not available
Cargo humidity sensor
available/not available
Dehumidification
operation ON/OFF