Indoor Unit
SiBE06-514A
138
Removal Procedure
4
Loosen the six screws
(three for the upper
side motor and three
for the bottom one) to
remove the fan motors.
Short lead wire: for the upper
fan motor
Long lead wire: for the
bottom fan motor
Mounting screw M4 × 16
5
Remove the motors
and cross flow fans.
Loosen the fixing screw to
separate the fan and motor.
6
To remove the casing,
loosen the four screws
at front side and the
other four screws at
rear side.
Casing mounting screw
Front: M4 × 16
Rear: M4 × 14
Condition : Casing
Protruded : Not to be removed
Semi-sink : To be removed
Sink : Not to be removed
Step
Procedure
Points