SiBE06-514A
Indoor Unit
Removal Procedure
137
1.6
Removal of the
Fan Rotor / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work
Step
Procedure
Points
1
For removal of the
drain pan, disconnect
the drain hose, then
loosen the two screws
located at left and right
sides.
Be careful not to wet the
floor with drain water.
Disengage harness for drain
pan from right side hook.
2
Remove the drain pan.
This swing motor is for down
flow shutter.
3
To remove the swing
motor on discharge
port of the drain pan,
loosen the two fixing
screws.