5
Loosen the fixing screw
to remove the pipe
retaining plate of the
heat exchanger.
Push the pipe retaining
plate backward to undo
the hook, then open the
retaining plate using
straight edge of screw-
driver to remove the
plate.
Mounting screw M4 × 16
6
Loosen the two screws
located at left side of
the heat exchanger.
Mounting screw M4 × 16
7
Pull left side of the heat
exchanger
toward
yourself, slide to right
to undo the hook
and remove the heat
exchanger.
Caution
When removing or re-
installing heat exchanger, be
sure to wear protective gloves
or wrap heat exchanger with
cloths. (Fins can cut fingers.)