SiBE06-514A
Troubleshooting
Service Diagnosis
107
Troubleshooting
Check No.06
Refer to P.120
P4
:
Radiation fin thermistor
J3
:
Discharge pipe thermistor
J6
:
Outdoor heat exchanger thermistor
H9
:
Outdoor air temperature thermistor
Turn on the power again.
Reconnect.
Reconnect.
Replace defective one(s) of
the following thermistors.
z
Radiation fin thermistor
z
Discharge pipe thermistor
z
Outdoor heat exchanger
thermistor
z
Outdoor air thermistor
Replace the following
thermistor.
z
Indoor heat exchanger
thermistor
Replace the outdoor unit
PCB. (Replace the indoor
unit PCB.)
(R4702)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Error displayed again
on remote controller?
NO
YES
YES
YES
NO
Indoor
heat exchanger thermistor
functioning?
NO
Connector or thermistor
disconnected?
NO
YES
Normal?
C
heck No.
06
Check the thermistor resistance
value.
C
heck No.
06
Check the indoor heat exchanger
thermistor resistance value in the
heating mode.
Summary of Contents for FVKS25BVMB
Page 10: ...SiBE06 514A List of Functions 1 Part 1 List of Functions 1 List of Functions 2 ...
Page 13: ...List of Functions SiBE06 514A 4 List of Functions ...
Page 19: ...Specifications SiBE06 514A 10 Specifications ...
Page 57: ...Control Specification SiBE06 514A 48 Function and Control ...
Page 85: ...Instruction SiBE06 514A 76 System Configuration ...
Page 133: ...Check SiBE06 514A 124 Service Diagnosis ...
Page 171: ...Others SiBE06 514A 162 Others ...
Page 177: ...Wiring Diagrams SiBE06 514A 168 Appendix ...
Page 181: ...SiBE06 514A iv Index ...