![background image](http://html1.mh-extra.com/html/daikin/ftyn25dv3b-aty20dv2/ftyn25dv3b-aty20dv2_service-manual_4216906031.webp)
Function of Thermistor
SiBE01-503
22
Functions and Control
2.
Function
of Thermistor
A
Outdoor Heat
Exchanger
Thermistor
(DCB)
1. The outdoor heat exchanger thermistor is used for high pressure control during cooling
operation.
B
Indoor Heat
Exchanger
Thermistor
(DCN)
1. The indoor heat exchanger thermistor is used to prevent freezing.
During the cooling operation, if the temperature drops abnormally, the operating frequency
becomes lower, then the operation must be halted.
Four way valve
Compressor
(R4733)
A
B