![background image](http://html1.mh-extra.com/html/daikin/ftyn25dv3b-aty20dv2/ftyn25dv3b-aty20dv2_service-manual_4216906089.webp)
Indoor Unit
SiBE01-503
80
Removal Procedure
1.4
Removal of
Electrical Parts Box / PCB /
Swing Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the front grill.
1. Remove the electrical
parts box.
1
Disconnect the
connection wires.
2
Disconnect the
connectors of
fan motor
(
S1
and
S7
).
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer will not touch the
harness (same as the
existing models.)
3
Disconnect the
connector of swing
motor (
S6
).
4
Remove
heat
exchanger thermistor
.
Summary of Contents for FTYN25DV3B ATY20DV2
Page 1: ...SiBE01 503 SPLIT Pair D Series Applied Models zNon Inverter Pair Heat Pump...
Page 5: ...SiBE01 503 iv Table of Contents Index i Drawings Flow Charts iii...
Page 10: ...SiBE01 503 List of Function 1 Part 1 List of Function 1 Functions 2...
Page 13: ...Functions SiBE01 503 4 List of Function...
Page 14: ...SiBE01 503 Specifications 5 Part 2 Specifications 1 Specifications 6...
Page 35: ...Control Specification SiBE01 503 26 Functions and Control...
Page 59: ...Instructions SiBE01 503 50 System Configuration...
Page 79: ...Check SiBE01 503 70 Service Diagnosis...
Page 117: ...Others SiBE01 503 108 Others...