2
|
Components
Service manual
141
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
Pins
Measured resistance (Ω)
7-8
465~535
7-9
7-10
8-9
8-10
9-10
Swing flap motor resistance
measurements are correct?
Action
Yes
Return to the troubleshooting of the
specific error and continue with the
next procedure.
No
Replace the swing flap motor, see
Repair procedures
INFORMATION
To replace the motor, the complete gearcase assembly MUST be replaced.
To remove the swing flap motor gearcase assembly
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Remove the main swing flap from the indoor unit (by clicking it out).
2
Remove the secondary swing flap from the indoor unit (by clicking it out).
3
Remove the right side fan guard from the indoor unit (by clicking it out).
c
a
b
a
Fan guard
b
Rocker arm
c
Swing raster
4
Remove the 3 screws from the swing flap motor gear case assembly. Do NOT
yet remove the assembly from the indoor unit.