![background image](http://html1.mh-extra.com/html/daikin/ftxa20a/ftxa20a_service-manual_2459411142.webp)
2
|
Components
Service manual
142
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
a
a
b
a
a
Screw
b
Swing flap motor gearcase assembly
5
Disconnect the rocker arm from the swing raster.
6
Remove the swing flap motor gear case assembly from the indoor unit.
7
Disconnect the harness from the swing flap motor.
8
Disconnect the harness from the swing raster motor.
9
To install the swing flap motor gearcase assembly, see
To install the swing flap motor gearcase assembly
1
Connect the harness to the swing raster motor connector.
2
Install the swing flap motor gearcase assembly on the indoor unit. Install the 3
screws, but do NOT yet tighten them.
a
a
b
a
a
Screw
b
Swing flap motor gearcase assembly
3
Connect the rocker arm to the swing raster.