![background image](http://html1.mh-extra.com/html/daikin/ftxa20a/ftxa20a_service-manual_2459411087.webp)
2
|
Components
Service manual
87
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
Is the problem solved?
Action
No
Return to
power PCB and continue with the next
procedure.
To remove a fuse of the indoor unit power PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Remove the fuse from the PCB.
a
a
Fuse F1U
2
To install a fuse on the indoor unit power PCB, see
To install a fuse on the indoor unit power PCB
1
Install the fuse on the correct location on the PCB.
CAUTION
Make sure the fuse is plugged‑in correctly (contact with the fuse holder).
a
a
Fuse F1U
Is the problem solved?
Action
Yes
No further actions required.