![background image](http://html1.mh-extra.com/html/daikin/ftxa20a/ftxa20a_service-manual_2459411061.webp)
2
|
Components
Service manual
61
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
b
Expansion valve coil harness
INFORMATION
The expansion valve and coil can have a different configuration / layout.
4
Cut all tie straps that fix the expansion valve coil harness.
5
Disconnect the expansion valve coil connector from the main PCB.
6
To install the expansion valve coil, see
To remove the expansion valve body
Prerequisite:
Recuperate the refrigerant from the refrigerant circuit, see
Prerequisite:
If needed, remove any parts or insulation to create more space for
the removal.
1
Remove the expansion valve coil, see
2
Remove the putty. Keep for re-use.
a
b
c
a
Putty
b
Expansion valve pipe
c
Expansion valve body
a
b
a
Expansion valve pipe
b
Expansion valve body
INFORMATION
The expansion valve and coil can have a different configuration / layout.
3
Using a valve magnet, open the expansion valve.