![background image](http://html1.mh-extra.com/html/daikin/ft25cv1a/ft25cv1a_service-manual_2459308181.webp)
R25/35CV1A, RY25/35CVMA
Si01-406
170
Removal Procedure
3.5
Removal of Compressor Noise Absorption Pad
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. To remove the
right side
plate
.
1
Remove the three
screws for removing the
right side plate.
2
Lift the right side plate
to disengage the hooks.
Insert the three hooks for the
restoration.
2. To remove the noise
absorber
Since the slit prepared for
the piping connection on the
noise absorption pad is torn
easily, remove the pad
carefully.
When restoring, the noise
absorption pad should pass
the internal side of the
piping.
1
Untie the string fixing
the body of the
compressor noise
absorption pad.