![background image](http://html1.mh-extra.com/html/daikin/ft25cv1a/ft25cv1a_service-manual_2459308096.webp)
Si01-406
Service Check Function
Service Diagnosis
85
3.2
ARC433 Series Remote Controller
The temperature display sections on the main unit indicate corresponding codes.
1. When the timer cancel button is held down for 5 seconds, a “
00
” indication flashes on the
temperature display section.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with a long beep.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No.
Code
No.
Code
No.
Code
1
00
11
E7
21
UA
2
U4
12
C7
22
A5
3
F3
13
H8
23
J9
4
E6
14
J3
24
E8
5
L5
15
A3
25
P4
6
A6
16
A1
26
L3
7
E5
17
C4
27
L4
8
LC
18
C5
28
H6
9
C9
19
H9
29
H7
10
U0
20
J6
30
U2
(R4114)
C
O N
TEMP
ON/OFF
POWERFUL
MODE
TIMER
FAN
ON
CANCEL
OFF
TIMER CANCEL button
It cancels the timer setting.