Instructions
Si01-406
74
System Configuration
Check
■
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
• Press “MODE selector button” and select “FAN” operation.
• Press “ON/OFF button” and start operation.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
NOTE
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the ser-
vice shop if this is the case.
• Operation with dirty filters:
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) the results in poor heating or cooling. (4) may cause odour.
• To order air purifying filter with photocatalytic deodorizing function contact to the service shop
where you bought the air conditioner.
• Dispose of old filters as burnable waste.
Item
Part No.
Air purifying filter with photocatalytic deodorizing
function. (with frame) 1 set
KAF918A43
Air purifying filter with photocatalytic deodorizing
function. (without frame) 1 set
KAF918A44