![background image](http://html1.mh-extra.com/html/daikin/ft25cv1a/ft25cv1a_service-manual_2459308183.webp)
R25/35CV1A, RY25/35CVMA
Si01-406
172
Removal Procedure
3.6
Removal of Partition Plate
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. To remove the partition plate.
1
Disengage the lead
wires from the wire clip.
2
Remove the two screws
fixing the partition plate.
3
Pull the partition plate
upward to remove.