![background image](http://html1.mh-extra.com/html/daikin/ft25cv1a/ft25cv1a_service-manual_2459308190.webp)
Si01-406
R50/60CV1A
Removal Procedure
179
4.3
Removal of Compressor
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Make sure that there is no
refrigerant in the unit
before disassembling.
WARNING
If refrigerant gas leaks during
servicing work, ventilate the
area. (If refrigerant gas
contacts flames, hazardous
gas can generate.)
When removing sound-
insulation material, do not
pull it with excessive force,
since it is inserted between
pipes.
1
Pull out sound
insulation material
(side
insulation) from right
side.
2
Disconnect
suction pipe
and
discharge pipe
of
compressor at brazed
sections.