![background image](http://html1.mh-extra.com/html/daikin/fdyb-ka-series/fdyb-ka-series_engineering-data_2460404064.webp)
ED41-016B
Installation
FDYB-KA Series
63
15.1.11 Outdoor Unit Installation
RY35
RY50
RY60
50 mm
or more
50 mm
or more
100 mm
or more
100 mm
or more
100 mm
or more
50 mm
or more
50 mm
or more
50 mm
or more
100 mm
or more
150 mm
or more
50 mm
or more
50 mm
or more
150 mm or more
300 mm or more
100 mm
or more
100 mm
or more
100 mm
or more
100 mm
or more
100 mm
or more
B
B
H
H : The height of the
wall on the air
discharge side
Anchor bolt hole pitch
A
B
Use turnbuckle
(on suction grille side)
C : 3PN00281-18T-12
〈
The following information is for RY35–50–60 outdoor unit types. Refer to the installation manual attached to the outdoor unit for other outdoor
unit types.
〉
〈
SELECTING INSTALLATION SITE
〉
Select an installation site where the following conditions are satisfied and that meets with your customer's approval.
•
Places which are well–ventilated.
•
Safe places which can withstand the unit's weight and vibration and where the unit can be installed level.
•
Places where the unit does not bother next-door neighbors.
•
Places where there is no possibility of flammable gas leak.
•
Places where things distressed in water do not exist because water drains off the outdoor unit.
•
Places where servicing space can be well ensured.
〈
INSTALLATION
〉
•
In case of bad drainage, build frames with concrete blocks, etc. under the outdoor unit.
•
To prevent the outdoor unit from falling or inclining from the frame, hang block strap around the hook or use turnbuckle.
H: 1000 mm or less
H: 1000 mm or more
B dimension
350
600
MODEL
RY35
RY50
RY60
A
290
330
370
B
530
540
500
[mm]
Summary of Contents for FDYB-KA Series
Page 11: ...Dimensions ED41 016B 10 FDYB KA Series FDYB50KA Unit mm C 3D024201B...
Page 12: ...ED41 016B Dimensions FDYB KA Series 11 FDYB60KA Unit mm C 3D024202B...
Page 13: ...Dimensions ED41 016B 12 FDYB KA Series FDYB71KA Unit mm C 3D024203B...
Page 14: ...ED41 016B Dimensions FDYB KA Series 13 5 2 Outdoor Units RY35F RY50GA Unit mm 3D004853B...
Page 17: ...Dimensions ED41 016B 16 FDYB KA Series RY250KU Unit mm C 3D029264...
Page 18: ...ED41 016B Dimensions FDYB KA Series 17 5 3 Installation Service Space For RY71 3D001951A 1...
Page 19: ...Dimensions ED41 016B 18 FDYB KA Series 3D001951A 2...
Page 20: ...ED41 016B Dimensions FDYB KA Series 19 For RY200 250 3D006578A...
Page 24: ...ED41 016B Piping Diagrams FDYB KA Series 23 RY250KUY1 Double Twin C 3D029828...
Page 29: ...Wiring Diagrams ED41 016B 28 FDYB KA Series 7 2 Outdoor Units 7 2 1 50Hz RY35FV1A RY50GAV1A...
Page 30: ...ED41 016B Wiring Diagrams FDYB KA Series 29 RY60GAV1A RY71KUV1 3D014495B...
Page 31: ...Wiring Diagrams ED41 016B 30 FDYB KA Series RY71KUY1 3D014603C...
Page 32: ...ED41 016B Wiring Diagrams FDYB KA Series 31 7 2 2 60Hz RY50GVAL RY60GVAL...
Page 33: ...Wiring Diagrams ED41 016B 32 FDYB KA Series RY71FUVAL RY200KUTAL 3D005370B 3D028902A...
Page 34: ...ED41 016B Wiring Diagrams FDYB KA Series 33 RY250KUTAL 3D028903A...
Page 49: ...Fan Performance ED41 016B 48 FDYB KA Series 11 Fan Performance 11 1 Fan Performance FDYB35KAVE...
Page 50: ...ED41 016B Fan Performance FDYB KA Series 49 FDYB50KAVE...
Page 51: ...Fan Performance ED41 016B 50 FDYB KA Series FDYB60KAVE FDYB71KAVE...
Page 54: ...ED41 016B Optional Accessories FDYB KA Series 53 Wireless Remote Controller BRC4C62 3D007898...